The alarm systems used for monitoring graphite safety discs provide a visual and acoustic alarm or trigger plant cutoffs. Two tantalum contacts or a contact finger in the alarm system press against the membrane of the safety disc and close the circuit of an amplifier relay. When the safety disc ruptures, the current circuit is interrupted and this triggers the alarm.
Advantages :
Corrosion resistance ensured by use of suitable materials
Reusability after safety disk rupture
Simple electrical connection via the 1.5 meter-long integral connecting cable
Used together with the matching amplifier relay, this system can also be operated in high explosion risk zones
Technical data :
Service voltage : AC 207V-253V, 45Hz – 60Hz, DC20 V – 30V
Circuit [EExia] II C, input as per DIN 19234 (Namur)
Output: 1 changeover AC 253 V / 2 A, DC 40 V / 2 A
The amplifier relay should be mounted outside the explosion risk zone
Vous cherchez des précisions complémentaires ? Demandez à être rappelé immédiatement.