Flexible fireproof protection

Method of protection :

A certified flexible fireproof protection is an effective method of protection of devices that control a plant which can minimize the danger and damages caused by fire in refineries, oil platforms, petrochemical plants, thermal power, electrical stations, and ship and defence fields.

Construction :

It is based on the assembly of several multilayered “jackets” fastened together. All covers are made by certified high performance materials designed to work in extreme temperature conditions:

    • external outer : -50°C up to approx. +275°C
    • full protection : up to +1200°C for a period of time, depending on specific requests

Benefits :

    • Easy to carry. They can be installed quickly without special tools, even by unqualified personnel
    • Installation may be carried out without stopping the system
    • Custom-made products for easy assembly and disassembly for maintenance of internal components
    • Weather, UV ray, chill, marine environment, chemical and acid resistant
    • Fire resistant up to 2hours with temperature of 1200°C

Applications : Fireproof product range is designed for effective fire protection of

    • Electric and pneumatic actuators
    • Check and regulation valves
    • Flanged couplings
    • Cable trays
    • Control and command panels
    • Pipe penetration passage
    • Rigid barriers

Conception :

Fireproof protection systems are designed and tailored to fit the shape of the component to be protected. It’s possible to create bays and holes to facilitate the exit of clutches, shafts, push-buttons and electric panels.

In order to ensure easy identification of the intervention place by the operator during emergencies, we may also manufacture some component parts in different colours.

Every component of our Fire protection is identified by special stainless steel plates with customer name, project reference, device tag code and other information requested by the buyer .

Certifications :

    • UL 1709 approvals from Underwriters Laboratories Inc. (USA)

The products are designed using a calculation method, production process and materials suitable to ensure a negligible temperature increase during the first 60/90 minutes exposure to fire.

Customized software :

The “fire safety engineering center” of Edinburgh University has developed for our plant customized software for fire protection design.

The program is able to emulate all the boundary conditions of the laboratories tests and to calculate the perfect thickness and resistance for every kind of request.

Lloyd’s Register U.K. has recognized its efficiency and accuracy through an international certification.

    • JET FIRE TEST J120 / Lloyd’s Register
    • BLAST TEST 1,85 BAR / Lloyd’s Register
PSAF001
PSAF002
PSAF003
PSAF004
PSAF005
Contact us

Rigid fire protection

Application : Valves, actuators, control panelsMaterials : Inox

  • AISI 304
  • AISI 316-AISI 316 L
  • AISI 321

The materials that cover the boxes are made of high density ceramic fibres absolutely asbestos-free.

Construction :

Hermetically sealed and filled with insulating materials having high hydrocarbon fire resistance till 1350° C. Easy-to-open inspection doors and openings can be made to reach command instruments and control display.

  • Flame temperature : 1100 °C
  • Time resistance : 30 ‘
  • Max. internal temperature : 135 °C
  • Regulation : UL1709
  • Certified by : Lloyd’s Register

Being tested

Contact us

Flame arrester

Purpose : To prevent the spread of an explosion.

Standards :

  • Directive 94/9/CE
  • ATEX 95
  • EN 12874

Notified bodies : IBExU & BAM

Medium and explosion groups :

  • I (Methane) MESG ≥ 1,14 mm
  • IIA (D) MESG > 0,90 mm
  • IIB3 (C) MESG ≥ 0,65 mm
  • IIC (B) MESG < 0,50 mm

Contact usDownload Technical Form

End of line flame arrester with flange : deflagration proof

Application : Gas, air, vapors for storage vents
Materials : Carbon steel, stainless steel
Connection :

  • DN25 to DN200
  • Flanges ISO PN16 / PN20 (150Lbs)
  • EN 12874

Options :

  • Temperature sensor (in case of continuous burning)
  • Intrinsically safe (E Ex i)

Some other type of end of line flame arresters may reach your need, feel free to contact us.

End of line flame arrester with flange

Contact us Download Technical Form

End of line flame arrester : deflagration proof with screwed end

Application : Gas, air, vapors for storage vents
Materials : Carbon steel, Stainless steel
Connection :

  • Ø 1″, 1″1/4, 1″1/2, 2″, 2″1/2, 3″
  • Female BSP or NPT end

Some other type of end of line flame arresters may reach your need, feel free to contact us.

End of line flame arresters with screwed end

Contact usDownload Technical Form

In line flame arrester with flanges : deflagration proof or detonation proof for unstable or stable detonation

Application : Gas, air, vapors ; to stop the propagation of detonation

Materials :

  • Carbon steel
  • Stainless steel
  • Hastelloy®
  • Carbon steel with Halar lining (for high corrosion)

Connection : DN25 to DN400 (1″ to 16″)

Options :

  • Temperature sensor (in case of continuous burning)
  • Intrinsically safe (E Ex i)

Some other type of in line flame arresters may reach your need, feel free to contact us.

AF_EL
A In line flame arrester with flanges

Download Technical Form
Download PDF
Contact us

In line flame arresters with screwed ends : deflagration proof or detonation proof for unstable or stable detonation

Application : Gas, air, vapors ; to stop the propagation of detonation

Materials : Carbon steel, stainless steel

Connections :

  • Ø 1/4″, 3/8″, 1/2″, 3/4″, 1″, 1″1/4, 1″1/2, 2″
  • BSP or NPT female ends
  • In line mounting

Options :

  • temperature sensor (in case of continuous burning)
  • Intrinsically safe (E Ex i)

Some other type of end of line flame arresters may reach your need, feel free to contact us.

In line flame arrester with screwed ends

Contact us
Download Technical Form

Breather valve with integrated flame arrester

The valve types VD / KS is a breather valve (pressure-vacuum) with integrated flame-arrester. It is designed to breathe tank openings.

VD/KS
Breather valve with integrated flamme-arrester

You can download the PDF file, the technical form and contact us by clicking on the icons.

ApplicationMainly used as equipment of fixed roof tanks for venting and inbreathing to prevent undue pressure resp. vacuum and undesired losses of vaporization, respectively undue emissions.

proof for products of explosion group IIA with a maximum experimental safe gap (MESG) > 0.9 mm.

ATEX 94/9/CE

Setting range :

  • from -3 mbar to -100 mbar (depending on the diameter)
  • from +10 mbar to +66 mbar (depending on the diameter)

Other possible settings contact us

Material :

  • Carbon steel, stainless steel
  • Gaskets : Perbunan®, Viton®, PTFE

Connections :

  • DN50, DN80, DN100
  • Flanges DIN EN1092-1 / ANSI 150 Lbs

Download PDFDownload technical formContact us

Several models of breaker valves with integrated flame-arrester exist, do not hesitate to contact us to discuss your needs.

Vacuum valve with integrated flame-arrester

The valves type VS/KS, are vacuum breaker with integreded flamme-arester.. Explosion proof safety valve to protect inbreathing openings of storage tanks, vessels and pipes to prevent inordinate vacuum.

VS/KS
vacuum breaker valve with integreded flamme-arester

You can download the PDF file, the technical form and contact us by clicking on the icons.

Application : Protection from vaccum and flamme for storage tanks and pipes.

Approved for flammable liquids of explosion group IIB3 with amaximum experimental safe gap (MESG) ≥ 0.65 mm.

ATEX 94/9/CE

Setting range : standard -1,4 mbar to -288 mbar (depending of the diameter) ; Other possible settings contact us

Material :

  • Carbon steel, stainless steel
  • gaskets : NBR, Viton®, PTFE

Connections :

  • DN50 to DN400
  • Flanges DIN EN1092-1 / ANSI 150 Lbs

Télécharger le PDFDownload technical formContact us

Several models of vacuum breaker valves with integrated flame-arrester exist, do not hesitate to contact us to discuss your needs.